GreaseMaster’s Utility Distribution System offers greater flexibility
over conventional utility connections.

Optional Equipment
• Light remote status indicator panel indicates status of breakers in wireway
• Electric outlet & cord sets water-tight pin, sleeve outlets, and cords
• Light & fan switches located in riser
• Hood control panel built directly into riser
• Ground fault protection
• Prison package
• Bumper strips
• Emergency kill switch. Single point shutdown of electrical power and electrical gas valves
• Swivel connectors for gas equipment
• Plumbing fixtures pre-plumbed & installed faucets, mixing valves and hose reels
• Cable restraints for mobile equipment
• Hinged doors for internal access to risers
• Temperature/pressure gauges for hot/cold water main



Product Overview
The GreaseMaster Utility Distribution System (UDS) allows greater flexibility over conventional utility connections. It is designed to provide additional capacity according to job specifications. Spare connection points are provided for future cooking equipment expansion, therefore, adding new equipment requires minimal effort. Rearranging the cooking line-up can be accomplished in a matter of minutes, especially when equipment is on casters.

Electrical Riser Power connection is made to the main circuit breaker which is equipped with a shunt trip and is mounted in the electrical riser.

Bus Bar Systems Electrical power is connected through the main circuit breaker to the bus bar system in the raceway. Each appliance is connected from the bus bar through individually sized circuit breakers located along the raceway.

Wireway Systems Electrical power is connected through a main circuit breaker to a distribution panel which contains individual branch breakers. Each appliance is fed from individual breakers which are wired to each receptacle located along the raceway.

Plumbing Riser The plumbing riser houses manual (quarterturn) shut-off valves for each incoming main supply line located in the UDS. The plumbing manifolds are provided with stub-outs along the raceway for the individual plumbing connections. Each stubout is equipped with a manual (quarter-turn) shut-off valve.

One Connection fo All Your Utility Needs
The GreaseMaster Utility Distribution System (UDS) is designed to meet all electrical and plumbing requirements for your kitchen appliances. A two compartment raceway houses either an electric copper bus bar or wireway which is completely isolated from the plumbing supply manifold.

The GreaseMaster UDS provides unequalled cooking line versatility, flexibility and convenience.

Features At a Glance
• ETL Listed and ETL Sanitation Listed product.
• Two models available: UDI (island configuration with equipment connections on both sides) and UDW (wall mounted with equipment connections on one side only).
• Expandability plumbing manifolds provided with multiple plumbing stubs for future use. Electrical systems are designed for additional capacity for future expansion or upgrade of connected appliances.
• Bus bar systems individual circuit breakers mounted on interchangeable plates for ease of service and relocation. Spare connection points provided for cooking equipment relocation or expansion.
• Wireway electrical distribution panel located in the riser is equipped with branch circuit breakers and sized for expansion.
• Serviceability and accessibility lift out doors provide easy access to risers without moving cooking equipment, in most cases. Removable panels provided along the length of the raceway allow access to either plumbing or electrical compartments.
• Electric outlets and cord sets all outlets are provided with moisture resistant covers and have been sized per NEMA standards. Each is supplied with a matching cord and plug set if these are not already supplied by the equipment manufacturer. Twist-lock sets are standard with the model UDI. Straight blade sets are standard with the model UDW.
• Main disconnect-one point disconnect through main circuit breaker equipped with 120 VAC rated shunt trip provided in riser.
• Gas solenoid valve-electrical or mechanical electrical valves provided with manual reset button.
• Shunt trip-provided with each main breaker.
• Appliance protection-each electrical outlet connection is protected with an individual circuit breaker.
• Dual convenience outlets-located at each riser with integral ground fault protection.
• Fire/fuel shutoff-In compliance with NFPA 96, terminal connection points provided for field wiring to the fire protection system to shut-off fuel sources and power in the event of a fire.